To adjust hysteresis, delay, or calibration, you usually need to press and hold the SET button for 3–5 seconds until "P0" (or similar code) appears.
When the relay turns ON in discharge mode, it will stay ON for at least seconds, even if the voltage immediately drops below dn . This prevents loads with high inrush current from causing the relay to turn OFF immediately. For example, an inverter might momentarily pull the battery voltage below dn when first powered on; FOP ignores that dip. A typical setting for inverters or pumps is 003 (3 seconds).
Setting XY-CD60 controller at ISTA Breeze charge controllers xycd60 manual
The XY-CD60 features a clean LCD layout and three simple navigation buttons: UP , DOWN , and SET .
A: This is usually due to voltage fluctuations at the threshold. Increase the difference between your UP and dn settings to create a larger hysterisis band.
. It is commonly used in solar setups to prevent battery damage from overcharging or deep discharging. The investigation suggests that the manual might be
Long press the SET button for 5 seconds to save and exit. Parameters Defined UP (Upper Limit): High voltage threshold. dn (Lower Limit): Low voltage threshold.
The is a highly versatile, dual-mode battery charge and discharge controller module . Operating across a wide voltage range of DC 6V to 60V , it acts as an intelligent switch designed to protect lead-acid, lithium-ion, and LiFePO4 batteries from overcharging and deep discharging. Crucial Note before operating: The Go to product viewer dialog for this item.
This occurs when the battery voltage fluctuates around the UP and dn thresholds, often due to high charger current or low battery capacity. The charger instantly reaches UP, the relay opens, the voltage drops to dn, and the relay closes again. Solutions include: This prevents loads with high inrush current from
VIN+ / VIN- (Input) and VOUT+ / VOUT- (Output) [as per Scribd User Manual ]. 3. Operating Modes (IN / OUT)
XY-CD60 Solar Battery Charge Controller Module - RoboFactory
is and cannot alter voltage or limit current . Instead, it uses an onboard relay to mechanically connect or disconnect your power source or load based on your customized upper and lower voltage parameters. Technical Specifications Specification Operating Voltage DC 6V to 60V Control Precision Output Type Relay Output (Physical Switch) Supported Batteries Lead-Acid, Lithium-Ion, LiFePO4, etc. Power Consumption < 1.5W (Approx. 30mA operating current) Physical Dimensions ~79mm x 43mm x 27mm Core Operating Modes